Appearance
Design Checks
General
The Blockwork Quay Wall design has been carried out in accordance with the requirements of BS EN 1997-1:2004+A1:2013, BS EN 1998-5:2004, and BS 6349-2:2019. Serviceability and Ultimate Limit State design methodology detailed in these codes and guides were followed to check that the structure was satisfactory. These limit states include:
- SLS – Serviceability Limit State
- ULS EQU (Set A) – Equilibrium Limit State
- ULS STR/GEO DA1C1 (Set B) – Structural and Geotechnical Limit State
- ULS STR/GEO DA1C2 (Set C) – Structural and Geotechnical Limit State
- ULS SEISMIC – Seismic Limit State
The partial factors and combination factors associated with each of these limit states are detailed in Design Factors. As an initial step, the relevant partial factors were applied to the relevant ground properties. Each action on the structure was then calculated in isolation such that for each block, there existed a set of forces and moments about its seaward base edge (toe) relating to each action. When assessing a block, actions on the block as well as on all blocks above were considered. The partial factors and combination factors were applied to the forces and moments calculated, and the factored actions were then used when designing against the principal modes of failure, which were chosen from the same codes and guides. These principal modes of failure include:
- Sliding
- Overturning
- Bearing
- Block-on-block toppling
Block-on-block toppling (EQU limit state) was checked by using Equation 1, BS EN 1997-1 (2.4), which states that the design value of the effect of destabilising actions, Edst;d, should be smaller than or equal to the design value of the effect of stabilising actions, Estb;d. Sliding, overturning and bearing (STR/GEO limit states) were checked by using Equation 2, BS EN 1997-1:2004 (2.5), which states that the design value of the effect of actions, Ed, should be smaller than or equal to the design value of the resistance, Rd. These equations are then used to give a utilisation factor – a value of 1 indicates that all of the partial factors of safety have been met, a value greater than 1 means that there is residual capacity in addition to the required partial factors of safety.
The partial factors associated with the limit state of static equilibrium (EQU) are applied to limit states relating to stability without failure of the ground or structural elements such as block on block toppling. Partial factors associated with the limit state of rupture/excessive deformation of either the ground or the structural elements (STR/GEO) are applied to modes of failure where this occurs such as in bearing, overturning and sliding.
Sliding Check
For each block, both Ed and Rd were calculated, and Equation 2 was verified. For sliding checks, Ed and Rd refer to the sum of the horizontal forces in the seaward or landward directions, respectively. Vertical forces that cause an anticlockwise or clockwise moment about a block's toe are added to Ed and Rd, respectively, after being factored by the coefficient of friction,
Figure 1: Sliding Check Visualisation
Overturning Check
For each block, both Ed and Rd were calculated, and Equation 2 was verified. For overturning checks, Ed and Rd refer to the sum of the moments acting in the anticlockwise or clockwise direction about a block's toe, respectively.
Figure 2: Overturning Check Visualisation
Bearing Check
For the base block, both Ed and Rd were calculated, and Equation 2 was verified. For bearing checks, Ed refers to the maximum bearing pressure, qmax, at the interface between the base of the block and the footing, B, and Rd refers to the bearing resistance of the footing. Additionally, the eccentricity, e, of the resultant of the vertical and horizontal actions was limited to 1/6 of B such that there was no uplift present at the base. This middle third check was also employed for all the other interfaces between block (block-on-block toppling) in the EQU case as this case deals with toppling specifically. The methodology of the bearing check was as follows:
Figure 3: Bearing scenario (left), e ≤ B/6 (middle), e > B/6 (right)
If
Figure 4: Bearing Check Visualisation
If