Skip to content

Design Factors ​

Partial Factors on Actions ​

In accordance with BS 6349-1-2 Table 1, the following partial factors have been applied:

LoadSLSEQUDA1C1DA1C2SEISMIC*
UFUFUFUFUF
C111.050.951.350.951111
W111.050.951.350.951111
S111.050.951.350.951111
SUU**111.5001.5001.30011
SUP**111.3501.3501.15000
SUS**111.3501.3501.15000
B***111.301.301.15000

* BS 6349-1-2:2016 Table 2 states that no partial factors, γ, are to be used in the Seismic case.

** SUU is conservatively taken as Cargo, and SUP & SUS as Equipment.

*** B taken from BS 6349-1-2:2016 Table 8 – Rated Capacity & Accidental Condition

The single source principal described in BS EN 1997-1:2004 states that "Unfavourable (or destabilising) and favourable (or stabilising) permanent actions may in some situations be considered as coming from a single source. If they are considered so, a single partial factor may be applied to the sum of these actions or to the sum of their effects". This principal was utilised in this design and the favourability of each source is detailed in the Table below:

LoadFavourability
CF
WU
SU
SUUU
SUPU
SUS*F
BU

* SUS set to U in bearing.

Partial Factors on Soil Properties ​

Certain soil parameters are also factored in accordance with BS EN 1997-1:2004 Annex A. These factors are applied by multiplying the inverse of the factor with the tangent of the parameter. For example, the design shearing resistance, φd′, is equal to tan−1⁡(tan⁡φ′γφ′), where γφ′ is the factor applied:

ParameterSLSEQUDA1C1DA1C2SEISMIC
Design Shearing Resistance, φd′*11.1**11.251.25
Design Angle of Friction, δd***11.1**11.251.25

* φd′ is used in block to foundation friction

** Taken from NA to BS EN 1997-1:2004 Table A.NA.2

*** δd is used in both wall friction and block to block friction

Combination Factors ​

Following the combination of actions methodology in BS 6349-1-2 Table 2, and in accordance with the values in BS 6349-1-2 Table 3, the following combination factors were applied to the following accompanying variable actions:

LoadSLSEQUDA1C1DA1C2SEISMIC
SUU*0.70.70.70.70.3
SUP*0.750.750.750.750
SUS*0.750.750.750.750
B0.50.50.50.50