The bollard loading was calculated by dividing the bollard capacity by the spacing between bollards. The mooring line was assumed horizontal as this created the largest destabilising moments so was the most conservative scenario. The bollard loads were found to be destabilising so an unfavourable partial load factor was applied to them and they were added to Ed.