Skip to content

Concrete ​

The blockwork wall will be constructed using a reinforced cope and unreinforced precast concrete blocks.

Self-Weight ​

The weight of each block was found by subtracting the volume of its chamfers from the volume of the block idealised as a cuboid and multiplying by the density of concrete. A percentage reduction to the weight due to lifting points and gaps between blocks was then applied to the blocks not cast in situ. Finally, the favourable partial load factor was applied. This action was stabilising so was added to Rd, and a cumulative weight with a cumulative centre of gravity (CoG) was used in the sliding and overturning checks for each block.

Inertia ​

This action is only non-zero in the seismic case. The horizontal inertia of each block idealised as a cuboid was found by multiplying the density of each block by its volume to get its mass, then multiplying by kh. The chamfer inertia is calculated in a similar manner and is subtracted from this value to get the horizontal inertia for each block. Finally, the unfavourable partial load factor was applied. The density of the blocks was not multiplied by (1-kv) for this action as horizontal inertia relies purely on mass and horizontal acceleration. This action was destabilising so was added to Ed, and a cumulative inertia with a cumulative centre of gravity (CoG) was used in the sliding and overturning checks for each block.