Skip to content

Earth Pressure ​

Static ​

The overall action caused by the soil was considered destabilising in line with the single source principal; therefore, an unfavourable partial load factor was applied to both horizontal and shear earth actions even though the shear action is stabilising. The horizontal action was added to Ed and the shear was added to Rd in line with their stabilities.

The vertical earth pressure distribution, sV, was calculated by multiplying the unit weight of earth, γS, by the height of the earth, h. The horizontal earth pressure distribution, sH, was then found by multiplying sV by the active earth pressure coefficient, K, which was calculated using Equation 26, BS EN 1998-5:2004 (E.2):

(24)sV=γS⋅h(25)sH=K⋅sV(26)K=sin2⁡(ψ+φd′−θ)cos⁡θsin2⁡ψsin⁡(ψ−θ−δd)[1+sin⁡(φd′+δd)sin⁡(φd′−β−θ)sin⁡(ψ−θ−δd)sin⁡(ψ+β)]2

Figure 6: Convention for angles in formulae for calculating the earth pressure coefficient (BS EN 1998-5: E.1)

ψ represents the inclination angle of the back of the wall from the horizontal line as shown in Figure 6. In this design, ψ is calculated for each block by finding the angle between the top right of the block being assessed and the top right of the block beneath. β represents the inclination angle of the backfill surface from the horizonal line and is set to 0. θ is also set to 0 in the static case.

The resultant earth force, S, on each block was then found by taking an average of sH at the top, sH,top, and bottom, sH,bot, of the block being assessed and multiplying by the thickness of the block, t. Due to the soil having a non-zero δd (the design value of the friction angle between the earth and the wall), and the wall having a non-zero ψ, the resultant force was resolved into horizontal, SH, and shear (vertical), SS actions in accordance with OCDI Part II Chapter 4 (2.2.7) & (2.2.8) by applying a cos⁡(ψ+δ) and sin⁡(ψ+δ) factor, respectively. Applied to the Eurocode convention, these equations are shown as Equations 28 and 29:

(27)S=sH,top+sH,bot2⋅t(28)SH=S⋅cos⁡([90−ψ]+δ)(29)SS=S⋅sin⁡([90−ψ]+δ)

The convention for ψ in OCDI is 'from the vertical' with a forwards lean defined as positive, whereas BS EN 1998-5 defines ψ as 'from the horizontal', meaning 90° has no lean. This is why ψ is used in OCDI and [90−ψ] is used in BS EN 1998-5.

Seismic ​

The calculation of the earth pressure in the seismic case was in line with BS EN 1998-5 Annex E and the brief methodology outlined in BS EN 1998-5 clause 7.3.2.3 (3) which states that "The design force should be considered to be the resultant force of the static and the dynamic earth pressures". In this way, both the static and dynamic earth pressures were required to be calculated. The static earth pressures were calculated following the procedure outlined in Static with θ set to 0. The static + dynamic earth pressures were calculated following the same procedure, with θ determined by BS EN 1998-5 E.6 and E.16, Equations 30 and 31, for soil above and pervious soil below the water table, respectively:

(30)tan⁡θ=kh1±kv(31)tan⁡θ=γdγ−γW⋅kh1±kv

Note that using calculated values of θ gives the static + dynamic earth pressures. Although the static and dynamic pressures are both taken into account, the way they are combined is not reflective of the earth pressure distribution in the seismic case according to BS EN 1998-5:2004 7.3.2.3 (4)P which states that "The point of application of the force due to the dynamic earth pressures shall be taken to lie at mid-height of the wall". In this way, the form of the dynamic earth pressures should be assumed rectangular and this distribution is called the seismic increment in some literature. This seismic increment is calculated by calculating the static + dynamic and the static forces in each block, subtracting them to get just the dynamic forces, summing these dynamic forces up, and dividing by the height of the soil layers. This gives a rectangular pressure distribution with a point of application at the mid-height of the wall. This distribution is added to the static distribution to get the seismic earth pressure distribution, which was used to calculate the forces and moments in each block.